Product Categories

Residential Inverter

FlexCube A

FlexCube A

Mobile Energy storage product

Application Scenarios

Weak power grids or off-grid areas, such as construction sites, highlands, islands, fishing villages, grasslands, and deserts. The diesel-storage system can serve as an independent power supply system, with the diesel generator providing supplementary power. 

Adaptable to Impact Load Equipment

FlexCube is compatible with impact load equipment such as water pumps, drilling rigs, lifts, and tower cranes.

Dual Charging Circuits, Simultaneous Charging and Discharging

The dual charging circuit design allows for simultaneous charging and discharging from weak power grids or diesel generators, ensuring stable operation of the microgrid.

Maintenance Bypass Design — No Downtime in  Case of Fault

In the event of unexpected situations, it can operate independently without service interruption. No cable removal is required — quick and convenient.

Easy Transport — Ready to Move and Use

The standard 10‑foot container and lightweight design allow for easy transport to different locations for deployment.

Quiet Operation

Peak operating noise is below 75 decibels, suitable for noise-sensitive environments.

Side Cable Outlet — Plug-and‑Play

The cabinet features a side cable outlet design, allowing it to be placed directly on flat ground for use without the need for a prefabricated base.

Multi-Unit Parallel Expansion

Power capacity can be flexibly configured to meet the power demands of various scenarios.

AI Cloud Platform for Intelligent Management

Remote management and maintenance, real-time data updates, and AI-powered intelligent analysis for efficient management.

 

Product Details

FlexCube-A Series Product Specifications

ModelFlexCube-250PFlexCube-250LFlexCube-500L
System Capacity250kW/161kWh250 kW / 261 kWh
(321 kWh optional)
500 kW / 402 kWh
(422/482 kWh optional)
System WiringThree-phase four-wire + PE
Grid-Connected Operation Mode 
Rated Output Power (kVA)250250500
Rated Output Current (A)361361722
Allowed Grid Voltage (Vac)400 (-15%~15%)
Isolation MethodPower Frequency Isolation
Allowed Grid Frequency (Hz)50±5/60±5
Total Current Harmonic Distortion Rate≤ 3%
Voltage Ripple Factor≤ 1%
Power Factor0.99/~1~10.99/~1~10.99/~1~1
Rated Input Power (kVA)250500500
Rated Input Current (A)361722722
Number of Grid-Connected UnitsDiesel generator does not support paralleling, Grid allows 4 units in parallel
Off-Grid Mode 
Rated Output Voltage (Vac)400
Output Voltage Distortion≤ 1% (linear load)
Rated Output Frequency (Hz)50/60
Grid/Off-Grid Switching DevicePresent
Number of Off-Grid Units4
Interaction Method 
RemoteCloud platform
LocalTouch screen
Battery Parameters 
Battery TypeLithium Iron Phosphate (LFP) Battery
System Nominal Voltage (V)512832704
Operating Voltage Range (V)464~576728~936616~792
Total Battery System Capacity (kWh)161261 (321 optional)422
Operating Temperature RangeCharging: 0°C to 45°C Discharging: -20°C to 45°C
Matching Diesel Generator/Grid Parameters—Slow Charging Port 
Wiring MethodThree-phase three-wire + PE
Input Voltage (Vac)320~485
Input Frequency (Hz)45~65
Power (kW)40 (*)40 (*)80 (*)
Communication MethodRS485
Matching Diesel Generator/Grid Parameters—Main Input Port 
Capacity≥ 125kW≥ 125kW≥ 250kW
Communication MethodRS485
System Parameters 
System Dimensions (W×H×D) (mm)1600*2300*25002500*2000*25912991*2438*2591
IP RatingIP54
Weight (kg)500091809460
Allowed Altitude (m)2000
Communication InterfaceEthernet, RS485, CAN

FlexCube-A Series Product Specifications

ModelFlexCube-250PFlexCube-250LFlexCube-500L
System Capacity250kW/161kWh250 kW / 261 kWh
(321 kWh optional)
500 kW / 402 kWh
(422/482 kWh optional)
System WiringThree-phase four-wire + PE
Grid-Connected Operation Mode 
Rated Output Power (kVA)250250500
Rated Output Current (A)361361722
Allowed Grid Voltage (Vac)400 (-15%~15%)
Isolation MethodPower Frequency Isolation
Allowed Grid Frequency (Hz)50±5/60±5
Total Current Harmonic Distortion Rate≤ 3%
Voltage Ripple Factor≤ 1%
Power Factor0.99/~1~10.99/~1~10.99/~1~1
Rated Input Power (kVA)250500500
Rated Input Current (A)361722722
Number of Grid-Connected UnitsDiesel generator does not support paralleling, Grid allows 4 units in parallel
Off-Grid Mode 
Rated Output Voltage (Vac)400
Output Voltage Distortion≤ 1% (linear load)
Rated Output Frequency (Hz)50/60
Grid/Off-Grid Switching DevicePresent
Number of Off-Grid Units4
Interaction Method 
RemoteCloud platform
LocalTouch screen
Battery Parameters 
Battery TypeLithium Iron Phosphate (LFP) Battery
System Nominal Voltage (V)512832704
Operating Voltage Range (V)464~576728~936616~792
Total Battery System Capacity (kWh)161261 (321 optional)422
Operating Temperature RangeCharging: 0°C to 45°C Discharging: -20°C to 45°C
Matching Diesel Generator/Grid Parameters—Slow Charging Port 
Wiring MethodThree-phase three-wire + PE
Input Voltage (Vac)320~485
Input Frequency (Hz)45~65
Power (kW)40 (*)40 (*)80 (*)
Communication MethodRS485
Matching Diesel Generator/Grid Parameters—Main Input Port 
Capacity≥ 125kW≥ 125kW≥ 250kW
Communication MethodRS485
System Parameters 
System Dimensions (W×H×D) (mm)1600*2300*25002500*2000*25912991*2438*2591
IP RatingIP54
Weight (kg)500091809460
Allowed Altitude (m)2000
Communication InterfaceEthernet, RS485, CAN

Get In Touch for More Information

Loading...

Related Products