ROSA T2

7.5-18kW LFP/VRLA2 MPPTs
 
ROSA T2 inverter is a three-phase, high-voltage hybrid inverter for residential use. With a new generation of industrial design and a brand new circuit topology, it fully meets the market demand for three-phase household models.
Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button


ROSA T2

Three Phase Hybrid Inverter
7.5-18kW 丨LFP/VRLA丨2 MPPTs



62.T2场景改(1)


  • Noise level below 25dB 

  • Supports 1.5 times transient overload 

  • Dust protection, water-resistant, impervious to water splashes 

  • Charging current of 33A, rapidly charging the battery

Model5kW6kW8kW10kW12kW
Battery Data




Battery TypeLithium-ion & Lead-acid
Rated Battery Voltage (Vdc)400
Battery Voltage Range (Vdc)135~800
Max. Charge/Discharge Current (A)33/33
PV Input




Max. Input Power (W)75009000120001500018000
Max. Input Voltage (Vdc)1000
Rated Input Voltage (Vdc)600
Start-Up Voltage (Vdc)120
MPPT Voltage Range (Vdc)180~900
No. Of MPPT/ Strings Per MPPT2/1+1
Max Input Current Per MPPT (A)16/16
Max. Short Circuit Current Per MPPT (A)20/20
Grid Input & Output




Rated Grid Voltage  (Vac)3L/N/PE, 400
Rated Grid Frequency (Hz)50
Rated Grid-Tied Power (W)5000600080001000012000
Rated Grid-Tied Current (A)7.38.711.614.517.4
Max Grid-Tied Apparent Power (VA)5500660088001100013200
Max Grid-Tied Current (A)8.41013.416.720
Max Input Apparent Power(VA)5500660088001100013200
Max Input Current(A)8.41013.416.720
Total Harmonic Distortion (THDi)<3%
Displacement Power Factor0.8 leading to 0.8 lagging
Backup Data




Rated Output Power (W)5000600080001000012000
Rated Output Current (A)8.41013.416.720
Rated Output Frequency (Hz)50
Overload Capability110%, continuous; 150%, 10s
Switch Time (ms)≤10
Total Harmonic Distortion (THDv)<3%
Efficiency




Max. Efficiency97.5%97.5%97.8%98.0%98.4%
Euro Efficiency96.8%97.1%97.1%97.3%97.3%
MPPT Efficiency99.9%
Protection




IntegratedPV Reverse-polarity Protection, PV Insulation Detection, Ground Fault Monitoring,
Over Current Protection, Over Voltage Protection
Surge ProtectionDC Type II / AC Type II
Over Voltage CategoryDC Type II / AC Type III
AFCIOptional
General Data




Operating Temperature (℃)-25 ~ +60 (Above 45℃ Derating)
Dimensions [W*H*D] (mm)565*465*197
Weight (kg)31
TopologyTransformerless
CoolingNatural Cooling
Altitude (m)≤3000
Protection LevelIP66
CommunicationRS485, WiFi/GPRS, CAN2.0
Warranty5 Years (Standard) / 10 Years (Optional)
Max. No. of Parallel Units6
Standard




Grid StandardsVDE-AR-N 4105, VDE0126-1-1, EN50549, CEI 0-21/16,EIFS,PSG,TOR
Safety StandardsIEC/EN 62109-1,IEC/EN 62109-2
EMC StandardsEN IEC 61000-6-1:2019、EN IEC 61000-6-3:2021、EN 61000-3-12:2011、EN IEC 61000-3-11:2019
Previous: 
Next: 

Related Products

ALPSOLARR

Providing top solutions for renewable energy and constantly creating value for our customers

ABOUT

PRODUCT

OTHERS

CONTACT

Room 301, Building B, Tongfang Information Harbor, No.11 Langshan Rd, Nanshan District, Shenzhen, Guangdong, China
 
 
Copyright ©️ 2024  Shenzhen Ligoo New Energy Technologies Co., Ltd. All Rights Reserved.